Safety switch and circuit breaker installation in Wangaratta and surrounding country areas.
Circuit breakers and safety switches protect your home in different ways. We install both, test them, and bring older switchboards up to the current standard, so the power stays on when it should and trips when it must.

30 mA
of leakage is where a safety switch trips
Up to 2 hrs
with the power off for a switchboard upgrade, planned around you
Every 2 years
is how often a Victorian rental needs an electrical safety check
Circuit breaker or safety switch?
A circuit breaker allows its full rated current to flow through a person. A safety switch trips after 30 mA of leakage and most times saves a life, which is why they are called safety switches.
- 1
A circuit breaker is the modern version of a fuse. If too much power is drawn, such as too many appliances plugged in, it trips and protects the circuit from catching fire or being damaged
- 2
A safety switch, also called a residual current device, picks up leakage current to earth. If someone gets a shock, or a cable is damaged and leaks, such as a wet lead in the grass, it picks up the imbalance between active and neutral and trips
When you need new ones
- 1
Renovating: any new circuit must have a safety switch, and circuits we work on behind an old safety switch are brought up to scratch
- 2
Adding solar: we upgrade the switchboard and bring the safety switches up to the current type
- 3
Renting out your home: in Victoria, all power outlets and lighting circuits in a rental need both a circuit breaker and a safety switch
- 4
Still on old porcelain fuses
- 5
Safety switches that keep tripping
Renting out your house
A Victorian rental needs an electrical safety check every two years. We do those rental checks, covering the switchboard and the wiring in the house, and give you a report on what needs attention. If you are going to rent your house out, you will need a switchboard with safety switches. A gas check is also required, and that is a job for a plumber, not for us. It matters just as much.
Old fuses are a risk
When we check porcelain fuses, nine times out of ten they have the wrong-rated fuse wire in them. Fuse wire makes it easy to fit the wrong wire or double it up. That is great for stopping the circuit tripping, but then a fire becomes the risk instead.
Nuisance tripping
Tripping does not always mean you need a new switchboard. Older boards had one safety switch, usually 40 amp, protecting several circuit breakers. When that safety switch trips, say because moisture has got into a septic pump in the country, it takes out every circuit on it. When we upgrade, we split them into combination units, with a safety switch and a circuit breaker on each circuit. A fault on the pump on a Saturday night then only switches off that one circuit. Old fridges and freezers in sheds can also leak a little through their ageing insulation, and a few small leaks plus a bit of moisture can tip a safety switch over the edge. The more we split circuits up, the less a slight leak matters, and the easier a fault is to find.
Why a safety switch trips
Think about when the power went off: was it the last light you turned on? Most faults disappear once everything has dried out, but not always. We are happy to talk you through it over the phone and save you a callout, or come out if you prefer. If you are not sure, keep it switched off and get an electrician to check.
- 1
An old fridge or freezer
- 2
Something as small as a raisin in a toaster
- 3
A power lead left out in the grass
- 4
An overfilled kettle, or a washing machine that has overflowed
- 5
Damaged insulation, or water in a light fitting after a storm
How we fit a switchboard
- 1
We isolate the mains for safety and let the power provider know we are turning the power off
- 2
We remove the old switchboard and usually build most of the new one beforehand, so the power is off for as little time as possible, up to two hours. If you work from home, we can do the turn-off at lunchtime
- 3
We carry out a main earthing test, trip tests on every safety switch, and an insulation test where required
- 4
We label every circuit clearly, so you know what is what
- 5
Whenever we do a main switch, an independent electrical inspector checks that it complies with the Victorian regulations
Quality that lasts
We use top-quality safety switches and circuit breakers, such as Clipsal, Schneider, Hager and NHP. We do not use cheap RCDs. The contacts and the insides are not as good and they do not last as long. Ask us, and we will pull one apart and show you what is inside.
Buying or selling?
Buying an old house? A brand-new switchboard with every circuit labelled looks great, and people assume the house has been rewired. That is not a safe assumption, so always get an electrical check done. Selling? A new switchboard presents well. First impressions count, and it shows a well-maintained house.
A safety switch that will not reset on a weekend
Some older safety switches are starting to fail, switching off and refusing to come back on. If that happens on a weekend, call or text us. We can talk you through getting the power back on until Monday. It is still safe, but it needs replacing.
The fault that only shows up when we are not there.
Sometimes a customer cannot reset their safety switch, and almost every time, as soon as we arrive, it switches on fine. We could spend four hours looking for an intermittent fault, which is not an efficient use of anyone's money. So we have a quick look, ask a lot of questions and test the safety switch. If the circuits are not split up and the customer is happy to invest, we split them into combination safety switches. When the fault returns, it is narrowed down to one circuit out of three instead of the whole lot, and a lot quicker and easier to find.

Questions about safety switch and circuit breaker installation in Wangaratta.
What is the difference between a circuit breaker and a safety switch?
A circuit breaker is the modern version of a fuse. It trips if too much power is drawn, protecting the circuit. A safety switch picks up leakage current to earth, such as a shock or a damaged cable, and trips at 30 mA, which most times saves a life.
Do rental properties need safety switches?
Yes. In Victoria, all power outlets and lighting circuits in a rental need both a circuit breaker and a safety switch. A rental also needs an electrical safety check every two years, and we do those checks.
Why does my safety switch keep tripping?
Common causes are an old fridge or freezer, a damaged lead, a washing machine that has overflowed, or water in a light fitting after a storm. Tripping does not always mean a new switchboard. We can split circuits so each has its own protection, so a fault only switches off one circuit.
How long is the power off for a switchboard upgrade?
Usually up to two hours. We build most of the new switchboard beforehand to keep it short, and if you work from home we can do the turn-off at lunchtime.
Is the work inspected?
Whenever we do a main switch, an independent electrical inspector checks that it complies with the Victorian regulations. We also test and label every circuit.
My safety switch will not reset on a weekend. What do I do?
Call or text us. We can talk you through getting the power back on until Monday. It is still safe, but it needs replacing.
More on circuit breakers and safety switch installs.
- An old board with fuses or one big safety switch can be made safe, and what a switchboard upgrade involves is explained step by step.
Electrical work in Victoria is regulated by Energy Safe Victoria. Buchan Electrical is a Registered Electrical Contractor, #16499.
Get a free quote
Tell Lachlan what needs doing and where. Text is best: he will always reply.